032-Tech Tips-Feature
Tuesday, November 11 14 / pdf

That is, they have an equivalent friction loss per unit length where the unit ... 5.2, Duct Design.) 7,500 cfm in three ducts with same EQUAL AREA Exact Cross-Equivalent Duct ...

HDPE_Final - NHAI
Saturday, October 10 14 / doc

... through NH No. No. of duct length (in ... supply 8 copies of the duct alignment sheets, detailed activity Bar chart ... failure within a distance equivalent to the length ...

MMV1153BA 03141A GB
Wednesday, June 06 14 / PDF

of all straight duct sections. The chart below shows you how to calculate total equivalent ductwork length using the approximate feet of equivalent length of

Medium Voltage Cable and Accessories
Sunday, June 06 14 / doc

AC and DC Voltage Tests: Each factory reel length shall ... cable and hand-taped splice from duct entrance to duct ... by the contractor shall be replaced with equivalent cable by ...

CoMbUSTion Air SySTeM
Wednesday, July 07 14 / pdf

page 2 SIZING AND SETUP Diagram A shows the maximum equivalent length and size of duct pipe that should be used when installing the CAS system. Using the chart will help ...

Chapter 1: Design Process
Monday, July 07 14 / doc

bioclimatic chart; climatic timetable; cross ventilation ... total equivalent length (length of run plus effective length ... burial, concrete encased duct, direct burial duct)

HARRIS COUNTY
Monday, November 11 14 / doc

Use no more than the equivalent of four 90-degree bends in any ... Provide underground warning tapes for exterior underground duct runs in continuous length ...

Weatherization Installer Intermediate Lesson Plans
Saturday, February 02 15 / doc

Equivalent duct length. Heat recovery ventilation (HRV) Home Ventilation Institute (HVI) ... Let students use the coverage chart to determine how many bags of ...

www.woodlinks.com
Wednesday, February 02 15 / doc

Static pressure (SP) of the worst drop an main duct can be calculated using the SP chart. ... of flex hose on your worst drop by 3 to calculate the equivalent length ...

GRILL-RANGE COOKTOP MODELS CONVERTIBLE NON-CONVERTIBLE
Thursday, January 01 15 / pdf

After reading these instructions, plan the duct run. Use the Duct Length Chart to find the equivalent length of the run. Shift the blower to High Range if indicated ...

COMBINED SPRINKLER AND STANDPIPE SYSTEMS-15305
Tuesday, April 04 15 / doc

vALVE CHART; Provide enclosed frame with chart ... access to all parts of piping systems and duct ... piping; threads shall be clean-cut of exact length.

Duct Design, Level 1: Fundamentals
Monday, March 03 15 / pdf

... will be able to manually size ductwork using either a friction chart or a duct ... Equivalent Length Method ...

1 Technical Requirements
Friday, February 02 15 / doc

Combustion Turbine Exhaust Duct 29. 6.2. Heat Recovery ... Filter media shall be Donaldson Spiderweb or equivalent with ... spacing of more than seven fins per inch of tube length ...

JVM 1790BK/CK/SK/WK GE Profile 1.7 Cu. Ft. Capacity Over-the ...
Thursday, August 08 14 / pdf

When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the ...

duct design st
Sunday, May 05 14 / pdf

1-In English unit chart (Fig. 12.21), the y-axis is the pressure drop per 100 ft length of the duct ... 2-Calculate the duct equivalent length (Le) 3-From the ...

. Installation Over the Range Instructions Microwave Oven
Saturday, April 04 15 / pdf

and adaptors plus the length of all straight duct sections. The chart below shows you how to calculate total equivalent ductwork length using the approximate feet

JOIST AND STRUCTURAL GLOSSARY
Tuesday, February 02 15 / doc

Alignment Chart for Columns . A nomograph for ... joist or joist girder to allow passage of a duct. ... The equivalent length, KL, used in compression formulas.

Air Flow, Air Systems, Pressure, and Fan Performance
Thursday, September 09 14 / DOC

... frictional loss per unit length is by using the Friction Chart ... the standard air density equivalent static ... L = Duct Section Length (ft) f = Friction Factor

UseCare / installation Manual
Monday, May 05 14 / pdf

Use this chart to calculate the equivalent duct length of your system. Broan Modem401 Straight Duct 3qn. 10qn. x 2-ft, long Equivalent length 2ft.

PIPE INSULATION SECTION 15260
Saturday, July 07 14 / doc

... codes when tested in composite form per one of the following nominally equivalent ... Corning insulation, may be supported by placing saddles of the proper length ...

SECTION 15890 - DUCTWORK AND ACCESSORIES
Thursday, August 08 14 / doc

Equivalent rolled steel structural support systems (such as TDF, TDC) may be used ... Provide at least two supports for each length of duct. Install supports on both sides ...

Abstract
Tuesday, January 01 15 / doc

Characteristic Design Parameter: Equivalent duct ... Relevant Analysis Parameter: Set Duct segment length L to ... calculates plot ranges for the CDPs, and a chart ...

ME07 - Fluid Mechanics
Saturday, July 07 14 / doc

This can be done from the data on the normal chart ... Sometimes losses are expressed in terms of equivalent length of ... included angle) and whether there is an outlet duct ...

Ductwork
Friday, December 12 14 / doc

Hinges shall be equivalent to Ventlok #370. Anchor casing by the use of ... Maximum flex duct length 6-0 (six feet), installed with no more ...

15800 Air Distribution
Tuesday, September 09 14 / doc

Maximum length of flexible duct to be 1500 mm (50). ... See fan chart and drawings for ... water-based high velocity duct sealer or equivalent ...

Ductsizing Maunfacturers charts
Sunday, May 05 14 / pdf

In fact, the length of duct shown on the chart is EFFECTIVE length, which is the sum of actual length and the equivalent length of the fittings. Some typical equivalent ...

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS
Monday, November 11 14 / pdf

c) The total equivalent length of the various duct runs, duct fittings and terminal devices. ... recommendations, the ACCA Manual D friction chart (Appendix 2, Chart 7 ...

6.Total Elect specs.doc
Saturday, July 07 14 / doc

... able to withstand a short circuit condition equivalent ... fitted outside the bus duct throughout the length of the bus duct ... Data flow chart with data at different points ...

MASTERCLASS - AIR CONDITIONING TECHNOLOGY PART 38 - NOVEMBER ISSUE
Wednesday, January 01 15 / pdf

... tables showing the either the pressure loss or the equivalent length of each fitting in the duct run ... Insert Chart 1 Duct Sections and Fittings Chart (1) Shows a summary of ...

HVAC Calculations and Duct Sizing
Friday, November 11 14 / pdf

Branch E has an equivalent length of 17 ft + 35 ft (elbow) = 52 ft. The loss ... ft. Locate the point.071 and 247cfm in an air friction chart. From this point read the duct ...

Engineering Data
Sunday, December 12 14 / pdf

Therefore, we have given you the quick reference chart approach to ... Fitting losses can be expressed as equivalent length of straight duct; or as a fraction of velocity ...

Installation Requirements
Tuesday, March 03 15 / pdf

If no data is available, use the generic flexible duct friction loss chart in ACCA ... the correct duct size, take into account the total equivalent length of the duct run ...

GE Monogram Chimney Vent Hood Installation Instructions, Elica ...
Monday, August 08 14 / pdf

DUCT FITTINGS Use this chart to compute maximum permissible lengths for duct runs to ... Equivalent length of duct pieces are based on actual tests conducted by GE ...

ange UseCare / installation Manual
Friday, September 09 14 / pdf

... White/Almond Cord Kit (Allowshoodtobe plugged intoa standard 120VAC wall outlet) Sears PartNo, 233,22HCK44D Ducting Accessories (SeeEquivalent Duct Length Charton page 5 for ...

DIVISION 15 - MECHANICAL
Thursday, February 02 15 / doc

Flexible duct shall have a minimum R-value of 6.0 and be constructed of ... of the fixture riser which shall be screwed into a 2 inch x 4 inch length of wood or equivalent ...

2011 Ventilation Fans
Tuesday, July 07 14 / PDF

shows you how to calculate the equivalent straight duct length in order to overcome static pressure. The EDL chart helps ensure fan performs as expected under